Salt Spray Testing: What 500 vs 1000 Hours Means
Salt spray testing is how chrome bar makers prove corrosion resistance. Stelmi America tests to the ASTM B117 neutral salt spray standard and rates results using ISO 10289, with in-house and certified independent laboratory testing.
- Stelmi 500: lasts 500+ hours in an ASTM B117 neutral salt spray chamber
- Stelmi 1000: lasts 1000+ hours in an ASTM B117 neutral salt spray chamber
- Corrosion resistance comes purely from the chrome plating, with no add-on treatment
- Virtually all test samples show zero corrosion after testing
Request a quote or call 269-781-6222
Specifications and details
The tests
| Term | Meaning |
|---|---|
| ASTM B117 | US standard practice for operating a neutral salt spray (fog) cabinet; samples are exposed continuously for a set number of hours |
| Neutral salt spray (NSS) | The salt solution used in ASTM B117 |
| ISO 10289 | Method for rating corrosion on plated samples after the test; a higher rating means less corrosion |
| Independent verification | Stelmi America verifies results in-house and with certified independent laboratories |
Which tier?
| Stelmi 500 | Stelmi 1000 | |
|---|---|---|
| Neutral salt spray (ASTM B117) | 500+ hr | 1000+ hr |
Choose the tier by the salt spray performance your equipment needs. For how the continuous process plates bar, see The Stelmi Process.
Related pages
Our family of companies
- Industrial Hard Chrome also tests its bar to ASTM B117: Industrial Hard Chrome.
Bar Technologies prepares the bar. Industrial Hard Chrome and Stelmi America plate it.
- Bar Technologies: Bar peeling (turning), centerless grinding and straightening. Geneva, IL
- Industrial Hard Chrome: Chrome plated bar, induction hardened bar and machined piston rods. Geneva, IL
- Stelmi America (this site): Long-length 500 / 1000 hr chrome plated bar. Marshall, MI
Request a quote or call 269-781-6222